P77.S/K106-A Piezoelectric Phase Shifter is designed for optical detection phase shifting applications. The diameter of its center aperture is 106mm. The load capacity of horizontal, vertical and inverted mounting can reach 10kg, 5kg and 5kg respectively. P77.S/K106-A series uses a piezoelectric ceramic direct drive structure to ensure the output performance, while the internal optimized mechanical structure design also provides perfect protection for the piezoelectric ceramics, ensuring the service life.
Characteristics
|
|
|
|
|
|
|
|
Technical data | |||
Models |
P77.S106-A |
Units |
|
Active axes |
Z |
|
|
Travel range(0~120V) |
14 |
μm±10% |
|
Max.travel range(0~150V) |
17.5 |
μm±10% |
|
Aperture |
Φ106 |
mm |
|
Resolution |
0.5/0.2 |
nm |
|
Pitch/Yaw/Roll |
<10 |
μrad |
|
Unloaded resonant frequency |
150 |
Hz±20% |
|
Unloaded Step time |
3.5 |
ms±20% |
|
Push/pull force |
100/50 | N | |
Load capacity |
Horizontal |
10 |
kg |
Vertical |
5 | ||
Inverted |
5 | ||
Electrical capacitance |
6.8 |
μF±20% |
|
Material |
Aluminum, steel |
|
|
Mass |
1900 |
g±5% |
|
Operating temperature |
-20~80 |
℃ |
|
Control |
1~3channel |
|
|
Connector |
LEMO |
|
|
Cable length |
1.5 |
m±10mm |
Note: Max driving voltage could be -20V~150V, Recommended voltage 0~120V for long-term operation to extend lifetime.
Technical data are measured by CoreMorrow E00/E01 series piezo controller.
Mounting Method |
Horizontal Mounting |
Vertical Mounting |
Inverted Mounting |
Definition |
Place the PZT platform horizontally for installation, with the moving surface located above the PZT platform and parallel to the horizontal plane.
PS: Default direction for carrying capacity in the parameter table
|
Place and install the PZT platform vertically, with the moving surface parallel to the direction of gravity
|
Place the PZT platform horizontally, but the moving surface is located below the PZT platform |
Diagram |
![]() |
![]() |
![]() |
Note |
When the mounting method is selected as vertical mounting, pay attention to the outlet port |
|
|
|