P16.XY50 series piezoelectric scanner is an XY-axis translation scanning platform adopting amplifying mechanism. The center through-hole aperture is 20mm. The series of scanners are available in 50μm travels, and the open-loop/closed loop is optional.
Characteristics
|
|
|
|
|
|
|
|
Appearance ![]() |
Moving-part ![]() |
Amplified-driving ![]() |
High Stiffness Large Load Capacity
P16.XY50 piezo scanner adopts principle of mechanism amplification design and built-in high-performance piezo ceramic. It can realize travel of 50μm. The integrated structure design has no coupling of XY axis motion. |
Freqency VS Load Curve ![]() |
Application Cases-XY Adjustment P16.XY piezo scanner is used in optical path adjustment experiment with its large load and high frequency. P16 carrying mirror frame to move precisely in XY axis. ![]() |
Applications
|
|
|
|
|
|
|
|
Technical data | |||
Models |
S-Closed loop |
P16.XY50S P16.XY50K |
Units |
Active axis |
X、Y |
|
|
Driving channels |
2 driving channels |
|
|
Travel range(0~120V) |
40/axis |
μm±10% |
|
Max.travel range(0~150V) |
50/axis |
μm±10% |
|
Sensor type |
SGS/- |
|
|
Aperture size |
Ø20 |
mm |
|
Resolution |
1.5/0.5 |
nm |
|
Linearity |
1/- |
%F.S |
|
Repeatability |
1/- |
%F.S |
|
Pitch/yaw/roll |
<20 |
μrad |
|
Push/pull force |
30/10 |
N |
|
Stiffness in motion direction |
0.5 |
N/μm±20% |
|
Unloaded resonant frequency |
500 |
Hz±20% |
|
Unloaded step time |
10/0.8 |
ms±20% |
|
Load capacity |
1.5 |
kg |
|
El.capacitance |
1.8/axis |
μF±20% |
|
Material |
Steel, Al |
|
|
Mass |
200 |
g±5% |
|
Load capacity |
Horizontal |
1.5 | kg |
Vertical |
0.05 | ||
Inverted |
1.5 |
Note: Above parameters are measured with the E00/E01 series piezo controller. The maximum driving voltage can be -20V~150V; for high reliability long-term use, the recommended driving voltage is 0~120V.
Mounting Method |
Horizontal Mounting |
Vertical Mounting |
Inverted Mounting |
Definition |
Place the PZT platform horizontally for installation, with the moving surface located above the PZT platform and parallel to the horizontal plane.
PS: Default direction for carrying capacity in the parameter table
|
Place and install the PZT platform vertically, with the moving surface parallel to the direction of gravity
|
Place the PZT platform horizontally, but the moving surface is located below the PZT platform |
Diagram |
![]() |
![]() |
![]() |
Note |
When the mounting method is selected as vertical mounting, pay attention to the outlet port |
|
|
|