The output voltage range of this series of bipolar piezo controllers can reach -320V to +320V, which can be used to drive piezo products such as piezo scanning tubes, and the number of channels can be freely selected.
Characteristics

|
|
|
|
|
|
Panel Introduction
|
Voltage vs Frequency Curves
|
| Technical Data | |||
|
Type |
E01.A2 |
E01.A6 |
E00.A12 |
|
Channels |
2 |
6 |
12 |
|
Analog input(V) |
-10~+10 |
-10~+10 |
-10~+10 |
|
Output voltage(V) |
-320~+320 |
-320~+320 |
-320~+320 |
|
Ripple(mV) |
20 |
20 |
20 |
|
Voltage stability |
<0.1%F.S./8 hours |
<0.1%F.S./8 hours |
<0.1%F.S./8 hours |
|
Input impedance(kΩ) |
100±20% |
100±20% |
100±20% |
|
Unloaded bandwidth(kHz) |
1 |
1 |
1 |
|
Ave. Current(mA) |
5 |
5 |
5 |
|
Peak current(mA) |
15 |
15 |
15 |
|
Bandwidth (1/10 signal)(kHz) |
5 |
5 |
5 |
|
Voltage gain |
32 |
32 |
32 |
|
Power supply |
AC 220V±10% 50Hz±10% |
AC 220V±10%,50Hz±10% |
AC 220V±10%,50Hz±10% |
|
Current limit |
Short-circuited proof, 8~9mA |
Short-circuited proof, 8~9mA |
Short-circuited proof, 8~9mA |
|
L×H×D(mm) |
280×175×375 |
280×175×375 |
500×375×175 |
|
Basic control way |
Analog control |
Analog control |
Analog control |
|